IEC 61000-4-4: Electrical Fast Transient / Burst Immunity Test immunity

Electronic products are tested to IEC 61000-4-4: Electrical Fast Transient / Burst Immunity Test immunity to insure their continued reliable operation if subjected to realistic levels of fast transients. The European Union’s EMC Directive mandates the Electrical Fast Transient / Burst Immunity Test testing for virtually all electrical and electronic products as a condition for […]

Susceptibility : Dips and Interrupts

Dips and interrupts can occur on the AC power mains as a result of a fault in the distribution system such as an open circuit breaker or a sudden large load being turned on in the immediate vicinity. A power distribution system fault can cause a switch in the distribution grid to open and close […]

Anechoic Chamber : EMC Testing UK

Anechoic Chambers Full Anechoic Chambers aim to absorb energy in all directions. Semi anechoic chambers have a solid floor that acts as a work surface for supporting heavy items, such as cars, washing machines, or industrial machinery, rather than the mesh floor grille over absorbent tiles found in full anechoic chambers. The floor is damped […]